Human OxLDL (Oxidized LowDensity Lipoprotein) ELISA Kit MSI1104
Cat: MSI1104
Assay Type: Competitive Inhibition
Detectable Sample Type: serum, plasma, cell lysates, cell culture supernates and other
biological fluids
Sensitivity: 0.51 ng/mL Detection Range: 1.57-100 ng/mL
Specificity: This assay has high sensitivity and excellent specificity for detection of Human OxLDL.
No significant cross-reactivity or interference between Human OxLDL and analogues was observed.
Description
Special Explanation
1. *If the kit is opened, Store the whole kit at 4°C. If the kit is not used up in 1 week. Store the Pre
Coated Microplate, Standard ,Biotinylated-Conjugate and Streptavidin-HRP at -20°C, the rest
reagents at 4°C, please used up within 6 months.
*If the kit is not opened, store the whole kit: 4°C(short time storage, valid for 6 months); -20°C
(long-term storage, valid for 1 year). Avoid repeated freeze-thaw cycles
2. Do not use the kit beyond the expiration date.
3. If the whole kit is stored at -20°C, place the kit at 4°C the day before the experiment.
4. After opening the package, please check that all components are complete.
5. The cap must be tightened to prevent evaporation and microbial contamination. The reagents
volume is slightly more than the volume marked on labels, please use accurate measuring
equipment and do not pour directly into the vial. All kit components have been formulated and quality control testedto function successfully. Do not mix
or substitute reagents or materials from other kits,guaranteed if utilized separately or substituted.
Materials Required, Not Supplied
1. Microplate reader capable of measuring absorbance at 450 ± 10 nm.
2. High-speed centrifuge.
3. Electro-heating standing-temperature cultivator.
4. Absorbent paper.
5. Double distilled water or deionized water.
6. Single or multi-channel pipettes with high precision and disposable tips.
7. Precision pipettes to deliver 2 μL to 1 mL volumes.
Safety Notes
1. This kit is only used for lab research and development and should not be used for human or
animals.
2. Reagents should be regarded as hazardous substances and should be handled carefully and
correctly.
3. Gloves, lab coats, and goggles should always be worn to avoid skin and eyes coming into contact
with Stop Reagent and TMB. In case of contact, wash thoroughly with water.
Test Principle
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate
provided in this kit has been pre-coated with Human OxLDL. Standards or samples are added to the
appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human OxLDL. Next,
Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated.
After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of
sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of
450nm ± 10nm. The concentration of Human OxLDL in the samples is then determined by comparing the
OD of the samples to the standard curve.